Services | Switchgear
MV & LV Switchgear Services
MV & LV Substation Maintenance
Switchgear failures can result in costly downtime, equipment damage and safety risks. We provide complete maintenance, repair and testing services for switchgear installations.
What we offer
Our Switchgear Services Include
Our maintenance programmes reduce downtime while ensuring maximum system reliability.
Installation & Commissioning
Routine Switchgear & BTU Maintenance
Busbar & Insulation Resistance Testing
Substation Refurbishment & Upgrades
Arc Flash Hazard Assessment & Mitigation
Retrofit Projects
Emergency Repairs
Need a switchgear service?
Our capabilities
Switchgear We Work On
We provide complete maintenance, repair and testing services for these switchgear types:
Oil switchgear (OCB)
SF6 gas switchgear
Vacuum circuit breakers (VCB)
Air circuit breakers (ACB)
Switchgear FAQs
Questions About Switchgear Maintenance
Common questions about 11kV switchgear servicing, switching and maintenance shutdowns.
How regularly should 11kV switchgear be serviced?
The frequency of 11kV switchgear maintenance depends on the switchgear type, operating environment and criticality of the installation. However, we recommend that all 11kV switchgear be inspected and tested annually as part of a preventative maintenance programme.
Annual preventative maintenance allows developing faults and deterioration to be identified at an early stage, including insulation deterioration, mechanical defects, loose connections, oil or gas-related issues and protection-system faults. Early identification of these conditions can help prevent costly equipment failures, unplanned outages and potential safety incidents.
For oil-insulated switchgear, the condition of the insulating oil can deteriorate over time due to contamination, moisture ingress and ageing. Deteriorated oil can result in reduced dielectric strength, increasing the risk of insulation breakdown, internal arcing or flashover.
What is 11kV switching?
Switching is the controlled process of isolating, de-energising, proving dead and safely earthing 11kV electrical equipment before maintenance can begin. It involves following an approved switching procedure to ensure that the correct equipment is isolated and cannot be accidentally re-energised while work is in progress.
11kV switching must only be performed by authorised and appropriately trained personnel. Personnel responsible for switching should have the required ORHV (Operational Rules for High Voltage) training and certification/authorisation applicable to the installation and network.
Because switching medium voltage equipment can present an arc-flash and electrical hazard, the person performing the switching must wear the specified arc-rated/fire-resistant switching suit and appropriate PPE required by the site’s electrical safety procedures and risk assessment. Switching is a critical safety function and must be carried out strictly in accordance with the approved switching programme, site procedures, manufacturer’s requirements and applicable electrical safety regulations.
Can you run the generator during a switchgear and transformer maintenance shutdown?
Yes, the generator can operate during an 11kV switchgear or transformer maintenance shutdown. The 11kV supply is temporarily isolated and the required switching, isolation and lockout procedures are implemented to ensure the maintenance area remains safely de-energised.
Talk to us about your switchgear
Need Switchgear Maintenance or Repairs?
Contact our team for a site assessment, a quote or technical advice.
Baymont Cape Projects provides 24-hour emergency and after-hours support for commercial, industrial and critical electrical installations across Cape Town and surrounding areas.